Unknown parameter letter

Parse errorThe file could not be read. Nothing is converted until the line is corrected.

What the converter says

unknown parameter 'F'

Code: unknown_param

What triggers it

A motion line uses a parameter letter the converter does not accept. Only X, Y, Z, I, J, V and T are recognised.

G1 X100.000 Y50.000 F600

Example that triggers it

How to fix it

Remove the parameter or replace it with the equivalent supported one. F for feed rate is a common import from generic G-code; Xilog Plus uses V.

Applies to

Messages this command can produce